Login | Register
新闻中心
Home > News > Company News

What should I do if the DC servo motor overheats? Cooling measures
2025-07-31 14:38:29

Overheating of DC servo motors not only reduces operating efficiency, but may also lead to insulation aging, shortened lifespan, and even trigger overheating protection shutdown. Targeted cooling measures should be taken based on the cause of overheating, as follows:


 


1、 First investigate the core cause of overheating


Abnormal load: If the motor continues to operate at more than 120% of the rated load (which can be monitored by the driver current), it will overheat due to a surge in copper and iron losses, manifested as a surface temperature of the motor exceeding 80 ℃ (when the ambient temperature is 30 ℃).


Poor heat dissipation: Malfunction of the cooling fan, accumulation of dust on the cooling fins, insufficient ventilation space, etc. can lead to the inability to dissipate heat in a timely manner, especially in enclosed environments.


Power or parameter issues: Input voltage too high (exceeding 10% of rated value), unreasonable setting of driver current loop parameters (such as excessive gain), can cause abnormal fluctuations in motor current and generate additional heat.


Mechanical jamming: Bearing wear, misalignment of the shaft system, load jamming, etc. can lead to increased mechanical losses, motor "holding back" heating, accompanied by abnormal noise or speed fluctuations during operation.


 


2、 Targeted cooling measures


(1) Reduce load and optimize operating parameters


1. Adjust the load matching degree


Use a torque tester to test the actual load. If it exceeds the rated torque of the motor, it is necessary to reduce the motor output torque through a mechanical reduction mechanism (such as adding a reducer), or replace it with a higher power model (such as upgrading a 100W motor to 150W); Bidirectional DC power supply, insulation withstand voltage test, Edwince


To avoid long-term full load operation of the motor, set a load upper limit protection (limit the peak current through driver parameters, usually 1.5 times the rated current) to prevent overload and overheating.


2. Optimize drive parameters


Enter the driver debugging interface and reduce the gain of the speed loop and current loop (such as reducing the proportional gain from 500 to 300) to minimize current fluctuations caused by parameter oscillations;


Enable the 'automatic energy-saving mode' (supported by some drivers) to automatically reduce the excitation current and minimize iron loss and heating during light loads.


(2) Enhance heat dissipation capability


1. Clean and upgrade heat dissipation components


Regularly (every 3 months) use compressed air to blow the dust on the motor heat sink and fan blades (especially in dusty workshop environments), ensuring that the heat dissipation area is fully utilized;


If the fan malfunctions (such as abnormal noise or stalling), promptly replace it with a cooling fan of the same specifications (pay attention to voltage matching, such as 24V DC), or upgrade it to a model with a larger air volume (such as replacing the 80mm fan with 120mm).


2. Improve the heat dissipation environment


The installation position of the motor should be away from heat sources (such as ovens and boilers), and if necessary, insulation barriers should be installed;


Axial flow fans or industrial air conditioners can be added to narrow spaces to control the ambient temperature below 40 ℃ (for every 10 ℃ increase in ambient temperature, the lifespan of the motor is reduced by about 50%);


For high-power motors (such as those above 500W), heat dissipation copper pipes can be wrapped around the casing and forced to cool down through a water cooling circulation system (suitable for high temperature environments).


(3) Addressing mechanical and electrical hazards


1. Eliminate mechanical blockages


Check the motor bearings: Rotate the motor shaft by hand. If you feel stuck or have excessive clearance, replace the bearings (choose a model filled with high-temperature grease, such as bearings that can withstand temperatures up to 150 ℃);


Calibrate the concentricity of the shaft system: Adjust the connection between the motor and the load through a laser centering instrument to ensure that the concentricity deviation is ≤ 0.1mm, reducing frictional heating caused by eccentricity.


2. Stable power input


Use a multimeter to measure the input voltage. If the fluctuation exceeds ± 5%, install an AC voltage regulator or DC power filter (such as an EMC filter) to reduce the current surge caused by voltage fluctuations;


Check the insulation resistance of the motor winding (measured with a megohmmeter, it should be ≥ 10M Ω). If the insulation is aging, it needs to be repainted and dried or the motor needs to be replaced to avoid internal short circuit heating.


 


3、 Daily monitoring and prevention


1. Install temperature monitoring device


Attach a temperature sensor (such as PT100) to the motor casing, monitor the temperature in real time through PLC or digital display instrument, set the alarm threshold (such as 75 ℃), and automatically stop the machine for protection in case of overheating;


Regularly use an infrared thermometer to detect the temperature of key parts such as the motor end and bearing seat, record the temperature change trend, and detect abnormalities in advance. Bidirectional DC power supply, insulation withstand voltage test, Edwince


2. Develop maintenance cycles


Check the operation status of the fan and the smoothness of the cooling channel every month;


Replace the bearing grease every six months (using high-temperature synthetic grease such as polyurea based grease);


Annual testing of motor insulation performance and winding resistance to ensure normal electrical performance.


Through the above measures, the temperature of the DC servo motor can be effectively controlled within a safe range (usually ≤ 70 ℃), ensuring its long-term stable operation. If the motor still frequently overheats after taking measures, it is necessary to check whether there are manufacturing defects (such as poor winding) in the motor, and if necessary, contact the manufacturer for maintenance or replacement.


 


 